IFM SD1540 SDD11DGXFRKG/US-100 Compressed Air Meter Arrived

IFM SD1540 SDD11DGXFRKG/US-100 Compressed Air Meter Arrived

 

 

IFM SD1540 SDD11DGXFRKG/US-100 Compressed Air Meter Arrived

 

Product characteristics of IFM PN3094 Pressure Sensor with Display PN-010-RER14-MFRKG/US/ /V Sensor In Stock


Compressed air meter SD1540 SDD11DGXFRKG/US-100

Precise measurement of flow, consumption, pressure and medium temperature

High accuracy, repeatability and measurement dynamics

For detecting compressed air in industrial use

With switching output, analog output and pulse output

Adjustable to inside pipe diameters

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1

Measuring range

0.6...143.9 m/s0.3...26260 m³/h0.005...437.6 m³/min

Process connectionthreaded connection G 1 Internal thread

Application

Applicationfor industrial applications

InstallationAdjustable to inside pipe diameters; ( 14...254 mm)

Mediacompressed air

Medium temperature[°C]-10...60

Min. bursting pressure

64 bar6.4 MPa

Pressure rating

16 bar1.6 MPa

MAWP (for applications according to CRN)[bar]10

Electrical data

Operating voltage[V]18...30 DC; (to SELV/PELV)

Current consumption[mA]< 80

Protection classIII

Reverse polarity protectionyes

Power-on delay time[s]1

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1

Inputs

Inputscounter reset

Outputs

Output signalswitching signal; analog signal; pulse signal; IO-Link; (configurable)

Electrical designPNP/NPN

Number of digital outputs2

Output functionnormally open / closed; (configurable)

Max. voltage drop switching output DC[V]2.5

Permanent current rating of switching output DC[mA]150; (per output)

Number of analog outputs1

Analog current output[mA]4...20; (scalable)

Max. load[Ω]500

Pulse outputconsumed quantity meter

Short-circuit protectionyes

Type of short-circuit protectionyes (non-latching)

Overload protectionyes

Measuring/setting range

Measuring range

0.6...143.9 m/s0.3...26260 m³/h0.005...437.6 m³/min

Display range

0...172.7 m/s0...31520 m³/h0...525.2 m³/min

Resolution

0.1 m/s0.05 m³/h0.01 m³/min

Set point SP

1.4...143.9 m/s0.8...26260 m³/h0.013...437.6 m³/min

Reset point rP

0.7...143.2 m/s0.4...26140 m³/h0.007...435.6 m³/min

Analog start point ASP

0...115.1 m/s0...21000 m³/h0...350 m³/min

Analog end point AEP

28.8...143.9 m/s422...26260 m³/h7.04...437.6 m³/min

Low flow cut-off LFC

0.2...1.4 m/s0.1...260 m³/h0.002...4.4 m³/min

In steps of

0.1 m/s0.01 m³/h0.001 m³/min

Pressure monitoring

Measuring range[bar]-1...16

Display range[bar]-1...20

Resolution[bar]0.05

Set point SP[bar]-0.92...16

Reset point rP[bar]-1...15.92

Analog start point[bar]-1...12.8

Analog end point[bar]2.2...16

In steps of[bar]0.01

Volumetric flow quantity monitoring

Measuring range

0...1000000000 m³0...35314666721 scf

Display range

0...1000000000 m³0...35314666721 scf

Set point SP

0.01...100000000 m³0.35...3531466672.1 scf

Pulse value

0.01...100000000 m³0.35...3531466672.1 scf

In steps of

0.001 m³0.05 scf

Pulse length[s]0.001...2

Temperature monitoring

Measuring range

-10...60 °C14...140 °F

Display range

-24...74 °C-11.2...165.2 °F

Resolution

0.2 °C0.5 °F

Set point SP

-9.7...60 °C14.6...140 °F

Reset point rP

-10...59.7 °C14...139.4 °F

Analog start point

-10...46 °C14...114.8 °F

Analog end point

4...60 °C39.2...140 °F

In steps of

0.1 °C0.1 °F

Accuracy / deviations

Temperature coefficient[1/K]± 0,07 % MW

Accuracy (in the measuring range)± (6 % MW + 0,6 % MEW); (reference conditions: diA = 73 mm; inlet pipe length >= 3 m; outlet pipe length >= 0,5 m; reference temperature: 20...25 °C; standard volume flow: 50...850 Nm³/h)

Repeatability± 1,5 % MW

Pressure monitoring

Repeatability[% of the final value]± 0,2

Characteristics deviation[% of the final value]< ± 0,5; (BFSL = Best Fit Straight Line)

Greatest TEMPCO of the span[% MEW / 10 K]± 0,3

Greatest TEMPCO of the zero point[% MEW / 10 K]± 0,1

Temperature monitoring

Accuracy[K]± 0,5; (medium flow in the limit area of the flow measurement range)

Reaction times

Response time[s]0.1; (dAP = 0)

Damping process value dAP[s]0...5

Pressure monitoring

Response time[s]0.05

Temperature monitoring

Dynamic response T05 / T09[s]T09 = 0,5

Software / programming

Parameter setting optionshysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer

Interfaces

Communication interfaceIO-Link

Transmission typeCOM2 (38,4 kBaud)

IO-Link revision1.1

SDCI standardIEC 61131-9 CDV

ProfilesDigital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000)

SIO modeyes

Required master port classA

Process data analog8

Process data binary2

Min. process cycle time[ms]7.2

Supported DeviceIDs

Type of operationDeviceID

default872

Operating conditions

Ambient temperature[°C]0...60

Storage temperature[°C]-20...85

Max. relative air humidity[%]90

ProtectionIP 65; IP 67

Tests / approvals

EMC

DIN EN 60947-5-9

CPA approval

model number-

accuracy class-

maximum allowable error± 7 % FS

Q (min)0,3 m³/h

Q (t)-

Q (max)26260 m³/h

Vibration resistance

DIN EN 68000-2-65 g (10...2000 Hz)

MTTF[years]167

UL approval

UL approval numberI013

File number ULE174189

Mechanical data

Weight[g]408.3

Housingrectangular

Dimensions[mm]85.1 x 45.8 x 100.3

MaterialPBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); stainless steel (1.4404 / 316L); FKM

Materials (wetted parts)stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate

Process connectionthreaded connection G 1 Internal thread

Displays / operating elements

Display

Color display 1,44", 128 x 128 pixels

2 x LED, yellow

Remarks

Remarks

MW = Measured value

MEW = Final value of the measuring range

D = inside pipe diameter

Measuring, display and setting ranges refer to standard volume flow according to DIN ISO 2533.

For information about installation and operation please see the operating instructions.

Pack quantity1 pcs.

Electrical connection

ConnectionConnector: 1 x M12; coding: A

 

 

 

 

More Models:

 

EVC810 IIR200 PK5524 EVC005 II0011 EVC004 SI5002 IGT205 O1D100 PQ3834IFS204TA2105IFM216EVF566II5930II5697EVC002IG5596SI5010II5687KF5015VTV122SA5000E21248 PN3094SI6700E30448OY039SEY3099E11855G1501SE11252PM1608AL1930EVC146EVT006LI5131PT5404PN7299PN7209AC1254AC1258SI6800EC2082AL1102UGT524EVC086EVC003 OGH500II5689AC5222AC5218AC5233SU7000PN3093PN2160IM5115SH0500LR2050MVQ101IFC248IFC234IFC220IN5225IFT203O5E700IG6086E12339IGC222EVC714IGW201IF5888 EVC597IM5126IGT220IG5505IG5401EVS023EVC812VTV121IIS204IM0011SM9000IGT213IFT205PN2093PN2094E20005OGE101OGS100PM1506E33403

 


We mainly supply Siemens, Schneider, Honeywell, ABB, Allen Bradley, Mitsubishi, Omron, Eaton, Pepperl+Fuchs, MTL, Phoenix Contact,Weidmuller, Festo, IFM, Wago, Pilz, Degson, Sick, SMC, Norgren, Yokogawa, Yaskawa, Fluke, SEW, Emerson,Endress+Hauser,Vega, Hirschmann,Moxa, CISCO, Turck, Beckhoff, B&R, Balluff, Bifold, GE,Rittal, Proface, Wintek,Danfoss,EBM, YTC,Hach,Delta, Finder,Wohner, CHINT, Autonics,Testo, Bently Nevada, PR Electronics, Meanwell, Dell and so on .

 

 

We are specialized in intelligent instruments, including : Transmitters, Flowmeters, Analyzers,Communicators, Safety Barriers, Sensors,Gas Detectors, PLC(DCS), Multimeters, Calibrators, Communicators, Recorder, Inverters, Positioners, Valves, Soft Starters, Circuit Breakers, Contactors, Rail Switches, Power Supply, HMI, Terminal Block, Relay etc.

 

 

Contact:

HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)

 

 

 

 